N6 Tolerance Chart (Hole N6)

Upper and lower deviations of hole N6 for nominal sizes 0–500 mm, per ISO 286-1. Values in mm; "+" means larger than nominal, "-" smaller. Calculate other sizes →

Nominal size (mm)Upper deviationLower deviationTolerance (IT)
0 ~ 3-0.004-0.0100.006
>3 ~ 6-0.005-0.0130.008
>6 ~ 10-0.007-0.0160.009
>10 ~ 18-0.009-0.0200.011
>18 ~ 30-0.011-0.0240.013
>30 ~ 50-0.012-0.0280.016
>50 ~ 80-0.014-0.0330.019
>80 ~ 120-0.016-0.0380.022
>120 ~ 180-0.020-0.0450.025
>180 ~ 250-0.022-0.0510.029
>250 ~ 315-0.025-0.0570.032
>315 ~ 400-0.026-0.0620.036
>400 ~ 500-0.027-0.0670.040

Each row applies to the whole size range shown. Ranges are "over the first value, up to and including the second".

How to read N6

N6 is an ISO 286 tolerance class. The uppercase letter N is the fundamental deviation (which side of the nominal size the tolerance zone lies on), and the number 6 is the tolerance grade IT6 (how wide the zone is). Transition (tight): N7/h6 is equivalent to H7/n6: almost always an interference, assembled with a press. N7 is used when a bearing outer ring must stay fixed in the housing. Typical processes for IT6: fine grinding, fine turning, fine boring: shafts for ordinary precision fits (g6, h6, k6, m6 dowel pins).

On a drawing or in a specification, Ø6 N6 and 6(-0.005/-0.013) mean the same thing — the second form writes the deviations out, so nobody has to look them up. SFP product specifications always use the second form.

Quick lookup for common sizes

Click "Calc" in the last column to open the calculator, where the written-out form can be copied with one click.

SizeUpper deviationLower deviationActual limits (mm)
Ø1-0.004-0.0100.990 ~ 0.996Calc
Ø1.5-0.004-0.0101.490 ~ 1.496Calc
Ø2-0.004-0.0101.990 ~ 1.996Calc
Ø2.5-0.004-0.0102.490 ~ 2.496Calc
Ø3-0.004-0.0102.990 ~ 2.996Calc
Ø4-0.005-0.0133.987 ~ 3.995Calc
Ø5-0.005-0.0134.987 ~ 4.995Calc
Ø6-0.005-0.0135.987 ~ 5.995Calc
Ø8-0.007-0.0167.984 ~ 7.993Calc
Ø10-0.007-0.0169.984 ~ 9.993Calc
Ø12-0.009-0.02011.980 ~ 11.991Calc
Ø13-0.009-0.02012.980 ~ 12.991Calc
Ø16-0.009-0.02015.980 ~ 15.991Calc
Ø20-0.011-0.02419.976 ~ 19.989Calc
Ø25-0.011-0.02424.976 ~ 24.989Calc
Ø30-0.011-0.02429.976 ~ 29.989Calc
Ø35-0.012-0.02834.972 ~ 34.988Calc
Ø40-0.012-0.02839.972 ~ 39.988Calc
Ø50-0.012-0.02849.972 ~ 49.988Calc
Ø60-0.014-0.03359.967 ~ 59.986Calc
Ø80-0.014-0.03379.967 ~ 79.986Calc
Ø100-0.016-0.03899.962 ~ 99.984Calc

Alternative classes (tighter)

The tolerance zones of the classes below lie entirely inside N6 (true for every size range from 0 to 500 mm), so they also satisfy a drawing that calls for N6. Those listed first are closest to N6; price and lead time still depend on material, size and stock.

N5

Related tolerance charts

FAQ

How big is N6 exactly?

It depends on the diameter. For Ø6, N6 means the part must measure between 5.987 and 5.995 mm, written 6(-0.005/-0.013). For other diameters see the chart above; every size range is listed.

Is N6 a hole tolerance or a shaft tolerance?

Letters in uppercase denote a hole (inside diameter). In lowercase, n6 is a shaft tolerance, lying on the opposite side of the nominal size.

The drawing calls for N6 but the parts I have are N5. Can I use them?

Yes. N5 is tighter than N6: at every diameter its limits fall inside the range N6 allows. The precision is simply higher than required, so the price may be a little higher.

Tell us the tolerance on your drawing and we will match it to stock. Write the size as 8(0/-0.015) or 8h7 and e-mail it with material, length and quantity to sfp@sfp-tw.com, or check availability directly in the online catalog. Stock dowel pins come in h6 / h7 / m6 as well as minus and plus tolerance; whenever the tolerance zone of a stock part lies entirely within the acceptance range on your drawing, it can ship straight away with no wait for custom production.

Values follow ISO 286-1; the table was cross-checked cell by cell against three independent sources on 2026-08-26 (6,674 cells agree, 0 errors). Coverage: shafts a–z and the corresponding uppercase holes, IT1–IT13, nominal sizes 0–500 mm. cd/ef/fg/za/zb/zc, sizes above 500 mm and grades above IT13 are not included: the tool reports "not found" and never extrapolates. Data sources and verification →

🔍 Open the online catalog🧮 Tolerance calculator