SFP Precision — Hardware Parts Platform
中文English日本語
Home › Tolerance Calculator › Hole G6 tolerance chart

G6 Tolerance Chart (Hole G6)

Upper and lower deviations of hole G6 for nominal sizes 0–500 mm, per ISO 286-1. Values in mm; "+" means larger than nominal, "-" smaller. Calculate other sizes →

Nominal size (mm)Upper deviationLower deviationTolerance (IT)
0 ~ 3+0.008+0.0020.006
>3 ~ 6+0.012+0.0040.008
>6 ~ 10+0.014+0.0050.009
>10 ~ 18+0.017+0.0060.011
>18 ~ 30+0.020+0.0070.013
>30 ~ 50+0.025+0.0090.016
>50 ~ 80+0.029+0.0100.019
>80 ~ 120+0.034+0.0120.022
>120 ~ 180+0.039+0.0140.025
>180 ~ 250+0.044+0.0150.029
>250 ~ 315+0.049+0.0170.032
>315 ~ 400+0.054+0.0180.036
>400 ~ 500+0.060+0.0200.040

Each row applies to the whole size range shown. Ranges are "over the first value, up to and including the second".

How to read G6

G6 is an ISO 286 tolerance class. The uppercase letter G is the fundamental deviation (which side of the nominal size the tolerance zone lies on), and the number 6 is the tolerance grade IT6 (how wide the zone is). Sliding (very small clearance): G7/h6 is the precision sliding fit on the shaft-basis system: slides freely with almost no play. Guide bushings, precision slides. Typical processes for IT6: fine grinding, fine turning, fine boring: shafts for ordinary precision fits (g6, h6, k6, m6 dowel pins).

On a drawing or in a specification, Ø6 G6 and 6(+0.012/+0.004) mean the same thing — the second form writes the deviations out, so nobody has to look them up. SFP product specifications always use the second form.

Quick lookup for common sizes

Click "Calc" in the last column to open the calculator, where the written-out form can be copied with one click.

SizeUpper deviationLower deviationActual limits (mm)
Ø1+0.008+0.0021.002 ~ 1.008Calc
Ø1.5+0.008+0.0021.502 ~ 1.508Calc
Ø2+0.008+0.0022.002 ~ 2.008Calc
Ø2.5+0.008+0.0022.502 ~ 2.508Calc
Ø3+0.008+0.0023.002 ~ 3.008Calc
Ø4+0.012+0.0044.004 ~ 4.012Calc
Ø5+0.012+0.0045.004 ~ 5.012Calc
Ø6+0.012+0.0046.004 ~ 6.012Calc
Ø8+0.014+0.0058.005 ~ 8.014Calc
Ø10+0.014+0.00510.005 ~ 10.014Calc
Ø12+0.017+0.00612.006 ~ 12.017Calc
Ø13+0.017+0.00613.006 ~ 13.017Calc
Ø16+0.017+0.00616.006 ~ 16.017Calc
Ø20+0.020+0.00720.007 ~ 20.020Calc
Ø25+0.020+0.00725.007 ~ 25.020Calc
Ø30+0.020+0.00730.007 ~ 30.020Calc
Ø35+0.025+0.00935.009 ~ 35.025Calc
Ø40+0.025+0.00940.009 ~ 40.025Calc
Ø50+0.025+0.00950.009 ~ 50.025Calc
Ø60+0.029+0.01060.010 ~ 60.029Calc
Ø80+0.029+0.01080.010 ~ 80.029Calc
Ø100+0.034+0.012100.012 ~ 100.034Calc

Alternative classes (tighter)

The tolerance zones of the classes below lie entirely inside G6 (true for every size range from 0 to 500 mm), so they also satisfy a drawing that calls for G6. Those listed first are closest to G6; price and lead time still depend on material, size and stock.

G5

Related tolerance charts

FAQ

How big is G6 exactly?

It depends on the diameter. For Ø6, G6 means the part must measure between 6.004 and 6.012 mm, written 6(+0.012/+0.004). For other diameters see the chart above; every size range is listed.

Is G6 a hole tolerance or a shaft tolerance?

Letters in uppercase denote a hole (inside diameter). In lowercase, g6 is a shaft tolerance, lying on the opposite side of the nominal size.

The drawing calls for G6 but the parts I have are G5. Can I use them?

Yes. G5 is tighter than G6: at every diameter its limits fall inside the range G6 allows. The precision is simply higher than required, so the price may be a little higher.

Tell us the tolerance on your drawing and we will match it to stock. Write the size as 8(0/-0.015) or 8h7 and e-mail it with material, length and quantity to sfp@sfp-tw.com, or check availability directly in the online catalog. Stock dowel pins come in h6 / h7 / m6 as well as minus and plus tolerance; whenever the tolerance zone of a stock part lies entirely within the acceptance range on your drawing, it can ship straight away with no wait for custom production.

Values follow ISO 286-1; the table was cross-checked cell by cell against three independent sources on 2026-08-26 (6,674 cells agree, 0 errors). Coverage: shafts a–z and the corresponding uppercase holes, IT1–IT13, nominal sizes 0–500 mm. cd/ef/fg/za/zb/zc, sizes above 500 mm and grades above IT13 are not included: the tool reports "not found" and never extrapolates. Data sources and verification →

🔍 Open the online catalog🧮 Tolerance calculator