Upper and lower deviations of shaft u6 for nominal sizes 0–500 mm, per ISO 286-1. Values in mm; "+" means larger than nominal, "-" smaller. Calculate other sizes →
| Nominal size (mm) | Upper deviation | Lower deviation | Tolerance (IT) |
|---|---|---|---|
| 0 ~ 3 | +0.024 | +0.018 | 0.006 |
| >3 ~ 6 | +0.031 | +0.023 | 0.008 |
| >6 ~ 10 | +0.037 | +0.028 | 0.009 |
| >10 ~ 18 | +0.044 | +0.033 | 0.011 |
| >18 ~ 24 | +0.054 | +0.041 | 0.013 |
| >24 ~ 30 | +0.061 | +0.048 | 0.013 |
| >30 ~ 40 | +0.076 | +0.060 | 0.016 |
| >40 ~ 50 | +0.086 | +0.070 | 0.016 |
| >50 ~ 65 | +0.106 | +0.087 | 0.019 |
| >65 ~ 80 | +0.121 | +0.102 | 0.019 |
| >80 ~ 100 | +0.146 | +0.124 | 0.022 |
| >100 ~ 120 | +0.166 | +0.144 | 0.022 |
| >120 ~ 140 | +0.195 | +0.170 | 0.025 |
| >140 ~ 160 | +0.215 | +0.190 | 0.025 |
| >160 ~ 180 | +0.235 | +0.210 | 0.025 |
| >180 ~ 200 | +0.265 | +0.236 | 0.029 |
| >200 ~ 225 | +0.287 | +0.258 | 0.029 |
| >225 ~ 250 | +0.313 | +0.284 | 0.029 |
| >250 ~ 280 | +0.347 | +0.315 | 0.032 |
| >280 ~ 315 | +0.382 | +0.350 | 0.032 |
| >315 ~ 355 | +0.426 | +0.390 | 0.036 |
| >355 ~ 400 | +0.471 | +0.435 | 0.036 |
| >400 ~ 450 | +0.530 | +0.490 | 0.040 |
| >450 ~ 500 | +0.580 | +0.540 | 0.040 |
Each row applies to the whole size range shown. Ranges are "over the first value, up to and including the second".
u6 is an ISO 286 tolerance class. The lowercase letter u is the fundamental deviation (which side of the nominal size the tolerance zone lies on), and the number 6 is the tolerance grade IT6 (how wide the zone is). Heavy interference: H7/u6: shrink or expansion fit; the interference transmits high torque and the joint is regarded as permanent. Railway wheels on axles, heavy-duty couplings. Typical processes for IT6: fine grinding, fine turning, fine boring: shafts for ordinary precision fits (g6, h6, k6, m6 dowel pins).
On a drawing or in a specification, Ø6 u6 and 6(+0.031/+0.023) mean the same thing — the second form writes the deviations out, so nobody has to look them up. SFP product specifications always use the second form.
Click "Calc" in the last column to open the calculator, where the written-out form can be copied with one click.
| Size | Upper deviation | Lower deviation | Actual limits (mm) | |
|---|---|---|---|---|
| Ø1 | +0.024 | +0.018 | 1.018 ~ 1.024 | Calc |
| Ø1.5 | +0.024 | +0.018 | 1.518 ~ 1.524 | Calc |
| Ø2 | +0.024 | +0.018 | 2.018 ~ 2.024 | Calc |
| Ø2.5 | +0.024 | +0.018 | 2.518 ~ 2.524 | Calc |
| Ø3 | +0.024 | +0.018 | 3.018 ~ 3.024 | Calc |
| Ø4 | +0.031 | +0.023 | 4.023 ~ 4.031 | Calc |
| Ø5 | +0.031 | +0.023 | 5.023 ~ 5.031 | Calc |
| Ø6 | +0.031 | +0.023 | 6.023 ~ 6.031 | Calc |
| Ø8 | +0.037 | +0.028 | 8.028 ~ 8.037 | Calc |
| Ø10 | +0.037 | +0.028 | 10.028 ~ 10.037 | Calc |
| Ø12 | +0.044 | +0.033 | 12.033 ~ 12.044 | Calc |
| Ø13 | +0.044 | +0.033 | 13.033 ~ 13.044 | Calc |
| Ø16 | +0.044 | +0.033 | 16.033 ~ 16.044 | Calc |
| Ø20 | +0.054 | +0.041 | 20.041 ~ 20.054 | Calc |
| Ø25 | +0.061 | +0.048 | 25.048 ~ 25.061 | Calc |
| Ø30 | +0.061 | +0.048 | 30.048 ~ 30.061 | Calc |
| Ø35 | +0.076 | +0.060 | 35.060 ~ 35.076 | Calc |
| Ø40 | +0.076 | +0.060 | 40.060 ~ 40.076 | Calc |
| Ø50 | +0.086 | +0.070 | 50.070 ~ 50.086 | Calc |
| Ø60 | +0.106 | +0.087 | 60.087 ~ 60.106 | Calc |
| Ø80 | +0.121 | +0.102 | 80.102 ~ 80.121 | Calc |
| Ø100 | +0.146 | +0.124 | 100.124 ~ 100.146 | Calc |
| Fit | Type | Typical use |
|---|---|---|
| H7/u6 | Interference | Heavy interference: shrink or expansion fit; the interference transmits high torque and the joint is regarded as permanent. Railway wheels on axles, heavy-duty couplings. |
The tolerance zones of the classes below lie entirely inside u6 (true for every size range from 0 to 500 mm), so they also satisfy a drawing that calls for u6. Those listed first are closest to u6; price and lead time still depend on material, size and stock.
It depends on the diameter. For Ø6, u6 means the part must measure between 6.023 and 6.031 mm, written 6(+0.031/+0.023). For other diameters see the chart above; every size range is listed.
Letters in lowercase denote a shaft (outside diameter). In uppercase, U6 is a hole tolerance, lying on the opposite side of the nominal size.
Yes. u5 is tighter than u6: at every diameter its limits fall inside the range u6 allows. The precision is simply higher than required, so the price may be a little higher.
Values follow ISO 286-1; the table was cross-checked cell by cell against three independent sources on 2026-08-26 (6,674 cells agree, 0 errors). Coverage: shafts a–z and the corresponding uppercase holes, IT1–IT13, nominal sizes 0–500 mm. cd/ef/fg/za/zb/zc, sizes above 500 mm and grades above IT13 are not included: the tool reports "not found" and never extrapolates. Data sources and verification →