SFP Precision — Hardware Parts Platform
中文English日本語
Home › Tolerance Calculator › Shaft p6 tolerance chart

p6 Tolerance Chart (Shaft p6)

Upper and lower deviations of shaft p6 for nominal sizes 0–500 mm, per ISO 286-1. Values in mm; "+" means larger than nominal, "-" smaller. Calculate other sizes →

Nominal size (mm)Upper deviationLower deviationTolerance (IT)
0 ~ 3+0.012+0.0060.006
>3 ~ 6+0.020+0.0120.008
>6 ~ 10+0.024+0.0150.009
>10 ~ 18+0.029+0.0180.011
>18 ~ 30+0.035+0.0220.013
>30 ~ 50+0.042+0.0260.016
>50 ~ 80+0.051+0.0320.019
>80 ~ 120+0.059+0.0370.022
>120 ~ 180+0.068+0.0430.025
>180 ~ 250+0.079+0.0500.029
>250 ~ 315+0.088+0.0560.032
>315 ~ 400+0.098+0.0620.036
>400 ~ 500+0.108+0.0680.040

Each row applies to the whole size range shown. Ranges are "over the first value, up to and including the second".

How to read p6

p6 is an ISO 286 tolerance class. The lowercase letter p is the fundamental deviation (which side of the nominal size the tolerance zone lies on), and the number 6 is the tolerance grade IT6 (how wide the zone is). Light interference: H7/p6: held by pressing in, but the interference alone cannot transmit much torque (add a key). Bushings pressed into housings, locating sleeves, bearing outer rings in housings under heavy load. Typical processes for IT6: fine grinding, fine turning, fine boring: shafts for ordinary precision fits (g6, h6, k6, m6 dowel pins).

On a drawing or in a specification, Ø6 p6 and 6(+0.020/+0.012) mean the same thing — the second form writes the deviations out, so nobody has to look them up. SFP product specifications always use the second form.

Quick lookup for common sizes

Click "Calc" in the last column to open the calculator, where the written-out form can be copied with one click.

SizeUpper deviationLower deviationActual limits (mm)
Ø1+0.012+0.0061.006 ~ 1.012Calc
Ø1.5+0.012+0.0061.506 ~ 1.512Calc
Ø2+0.012+0.0062.006 ~ 2.012Calc
Ø2.5+0.012+0.0062.506 ~ 2.512Calc
Ø3+0.012+0.0063.006 ~ 3.012Calc
Ø4+0.020+0.0124.012 ~ 4.020Calc
Ø5+0.020+0.0125.012 ~ 5.020Calc
Ø6+0.020+0.0126.012 ~ 6.020Calc
Ø8+0.024+0.0158.015 ~ 8.024Calc
Ø10+0.024+0.01510.015 ~ 10.024Calc
Ø12+0.029+0.01812.018 ~ 12.029Calc
Ø13+0.029+0.01813.018 ~ 13.029Calc
Ø16+0.029+0.01816.018 ~ 16.029Calc
Ø20+0.035+0.02220.022 ~ 20.035Calc
Ø25+0.035+0.02225.022 ~ 25.035Calc
Ø30+0.035+0.02230.022 ~ 30.035Calc
Ø35+0.042+0.02635.026 ~ 35.042Calc
Ø40+0.042+0.02640.026 ~ 40.042Calc
Ø50+0.042+0.02650.026 ~ 50.042Calc
Ø60+0.051+0.03260.032 ~ 60.051Calc
Ø80+0.051+0.03280.032 ~ 80.051Calc
Ø100+0.059+0.037100.037 ~ 100.059Calc

Common fits

FitTypeTypical use
H7/p6InterferenceLight interference: held by pressing in but unable to transmit much torque on its own (add a key). Bushings pressed into housings, locating sleeves, heavily loaded bearing outer rings in housings.

Alternative classes (tighter)

The tolerance zones of the classes below lie entirely inside p6 (true for every size range from 0 to 500 mm), so they also satisfy a drawing that calls for p6. Those listed first are closest to p6; price and lead time still depend on material, size and stock.

p5

Related tolerance charts

FAQ

How big is p6 exactly?

It depends on the diameter. For Ø6, p6 means the part must measure between 6.012 and 6.020 mm, written 6(+0.020/+0.012). For other diameters see the chart above; every size range is listed.

Is p6 a shaft tolerance or a hole tolerance?

Letters in lowercase denote a shaft (outside diameter). In uppercase, P6 is a hole tolerance, lying on the opposite side of the nominal size.

The drawing calls for p6 but the parts I have are p5. Can I use them?

Yes. p5 is tighter than p6: at every diameter its limits fall inside the range p6 allows. The precision is simply higher than required, so the price may be a little higher.

Tell us the tolerance on your drawing and we will match it to stock. Write the size as 8(0/-0.015) or 8h7 and e-mail it with material, length and quantity to sfp@sfp-tw.com, or check availability directly in the online catalog. Stock dowel pins come in h6 / h7 / m6 as well as minus and plus tolerance; whenever the tolerance zone of a stock part lies entirely within the acceptance range on your drawing, it can ship straight away with no wait for custom production.

Values follow ISO 286-1; the table was cross-checked cell by cell against three independent sources on 2026-08-26 (6,674 cells agree, 0 errors). Coverage: shafts a–z and the corresponding uppercase holes, IT1–IT13, nominal sizes 0–500 mm. cd/ef/fg/za/zb/zc, sizes above 500 mm and grades above IT13 are not included: the tool reports "not found" and never extrapolates. Data sources and verification →

🔍 Open the online catalog🧮 Tolerance calculator