f8 Tolerance Chart (Shaft f8)

Upper and lower deviations of shaft f8 for nominal sizes 0–500 mm, per ISO 286-1. Values in mm; "+" means larger than nominal, "-" smaller. Calculate other sizes →

Nominal size (mm)Upper deviationLower deviationTolerance (IT)
0 ~ 3-0.006-0.0200.014
>3 ~ 6-0.010-0.0280.018
>6 ~ 10-0.013-0.0350.022
>10 ~ 18-0.016-0.0430.027
>18 ~ 30-0.020-0.0530.033
>30 ~ 50-0.025-0.0640.039
>50 ~ 80-0.030-0.0760.046
>80 ~ 120-0.036-0.0900.054
>120 ~ 180-0.043-0.1060.063
>180 ~ 250-0.050-0.1220.072
>250 ~ 315-0.056-0.1370.081
>315 ~ 400-0.062-0.1510.089
>400 ~ 500-0.068-0.1650.097

Each row applies to the whole size range shown. Ranges are "over the first value, up to and including the second".

How to read f8

f8 is an ISO 286 tolerance class. The lowercase letter f is the fundamental deviation (which side of the nominal size the tolerance zone lies on), and the number 8 is the tolerance grade IT8 (how wide the zone is). Close running: H7/f7 and H8/f7 are the usual general-purpose running fits: gearbox shafts and bushings, plain bearings at medium speed and load, pump and motor shafts. Typical processes for IT8: turning, reaming, milling, broaching: fits of ordinary accuracy (H8, f7).

On a drawing or in a specification, Ø6 f8 and 6(-0.010/-0.028) mean the same thing — the second form writes the deviations out, so nobody has to look them up. SFP product specifications always use the second form.

Quick lookup for common sizes

Click "Calc" in the last column to open the calculator, where the written-out form can be copied with one click.

SizeUpper deviationLower deviationActual limits (mm)
Ø1-0.006-0.0200.980 ~ 0.994Calc
Ø1.5-0.006-0.0201.480 ~ 1.494Calc
Ø2-0.006-0.0201.980 ~ 1.994Calc
Ø2.5-0.006-0.0202.480 ~ 2.494Calc
Ø3-0.006-0.0202.980 ~ 2.994Calc
Ø4-0.010-0.0283.972 ~ 3.990Calc
Ø5-0.010-0.0284.972 ~ 4.990Calc
Ø6-0.010-0.0285.972 ~ 5.990Calc
Ø8-0.013-0.0357.965 ~ 7.987Calc
Ø10-0.013-0.0359.965 ~ 9.987Calc
Ø12-0.016-0.04311.957 ~ 11.984Calc
Ø13-0.016-0.04312.957 ~ 12.984Calc
Ø16-0.016-0.04315.957 ~ 15.984Calc
Ø20-0.020-0.05319.947 ~ 19.980Calc
Ø25-0.020-0.05324.947 ~ 24.980Calc
Ø30-0.020-0.05329.947 ~ 29.980Calc
Ø35-0.025-0.06434.936 ~ 34.975Calc
Ø40-0.025-0.06439.936 ~ 39.975Calc
Ø50-0.025-0.06449.936 ~ 49.975Calc
Ø60-0.030-0.07659.924 ~ 59.970Calc
Ø80-0.030-0.07679.924 ~ 79.970Calc
Ø100-0.036-0.09099.910 ~ 99.964Calc

Alternative classes (tighter)

The tolerance zones of the classes below lie entirely inside f8 (true for every size range from 0 to 500 mm), so they also satisfy a drawing that calls for f8. Those listed first are closest to f8; price and lead time still depend on material, size and stock.

Related tolerance charts

FAQ

How big is f8 exactly?

It depends on the diameter. For Ø6, f8 means the part must measure between 5.972 and 5.990 mm, written 6(-0.010/-0.028). For other diameters see the chart above; every size range is listed.

Is f8 a shaft tolerance or a hole tolerance?

Letters in lowercase denote a shaft (outside diameter). In uppercase, F8 is a hole tolerance, lying on the opposite side of the nominal size.

The drawing calls for f8 but the parts I have are f7. Can I use them?

Yes. f7 is tighter than f8: at every diameter its limits fall inside the range f8 allows. The precision is simply higher than required, so the price may be a little higher.

Tell us the tolerance on your drawing and we will match it to stock. Write the size as 8(0/-0.015) or 8h7 and e-mail it with material, length and quantity to sfp@sfp-tw.com, or check availability directly in the online catalog. Stock dowel pins come in h6 / h7 / m6 as well as minus and plus tolerance; whenever the tolerance zone of a stock part lies entirely within the acceptance range on your drawing, it can ship straight away with no wait for custom production.

Values follow ISO 286-1; the table was cross-checked cell by cell against three independent sources on 2026-08-26 (6,674 cells agree, 0 errors). Coverage: shafts a–z and the corresponding uppercase holes, IT1–IT13, nominal sizes 0–500 mm. cd/ef/fg/za/zb/zc, sizes above 500 mm and grades above IT13 are not included: the tool reports "not found" and never extrapolates. Data sources and verification →

🔍 Open the online catalog🧮 Tolerance calculator