Upper and lower deviations of hole K7 for nominal sizes 0–500 mm, per ISO 286-1. Values in mm; "+" means larger than nominal, "-" smaller. Calculate other sizes →
| Nominal size (mm) | Upper deviation | Lower deviation | Tolerance (IT) |
|---|---|---|---|
| 0 ~ 3 | 0 | -0.010 | 0.010 |
| >3 ~ 6 | +0.003 | -0.009 | 0.012 |
| >6 ~ 10 | +0.005 | -0.010 | 0.015 |
| >10 ~ 18 | +0.006 | -0.012 | 0.018 |
| >18 ~ 30 | +0.006 | -0.015 | 0.021 |
| >30 ~ 50 | +0.007 | -0.018 | 0.025 |
| >50 ~ 80 | +0.009 | -0.021 | 0.030 |
| >80 ~ 120 | +0.010 | -0.025 | 0.035 |
| >120 ~ 180 | +0.012 | -0.028 | 0.040 |
| >180 ~ 250 | +0.013 | -0.033 | 0.046 |
| >250 ~ 315 | +0.016 | -0.036 | 0.052 |
| >315 ~ 400 | +0.017 | -0.040 | 0.057 |
| >400 ~ 500 | +0.018 | -0.045 | 0.063 |
Each row applies to the whole size range shown. Ranges are "over the first value, up to and including the second".
K7 is an ISO 286 tolerance class. The uppercase letter K is the fundamental deviation (which side of the nominal size the tolerance zone lies on), and the number 7 is the tolerance grade IT7 (how wide the zone is). Transition: K7/h6 is equivalent to H7/k6: a small chance of interference, assembled with light hammer blows, removable and well centred. K7 is common for bearing outer rings in housings. Typical processes for IT7: fine turning, reaming, fine boring: the usual grade for fitted holes (H7) and h7 dowel pins.
On a drawing or in a specification, Ø6 K7 and 6(+0.003/-0.009) mean the same thing — the second form writes the deviations out, so nobody has to look them up. SFP product specifications always use the second form.
Click "Calc" in the last column to open the calculator, where the written-out form can be copied with one click.
| Size | Upper deviation | Lower deviation | Actual limits (mm) | |
|---|---|---|---|---|
| Ø1 | 0 | -0.010 | 0.990 ~ 1.000 | Calc |
| Ø1.5 | 0 | -0.010 | 1.490 ~ 1.500 | Calc |
| Ø2 | 0 | -0.010 | 1.990 ~ 2.000 | Calc |
| Ø2.5 | 0 | -0.010 | 2.490 ~ 2.500 | Calc |
| Ø3 | 0 | -0.010 | 2.990 ~ 3.000 | Calc |
| Ø4 | +0.003 | -0.009 | 3.991 ~ 4.003 | Calc |
| Ø5 | +0.003 | -0.009 | 4.991 ~ 5.003 | Calc |
| Ø6 | +0.003 | -0.009 | 5.991 ~ 6.003 | Calc |
| Ø8 | +0.005 | -0.010 | 7.990 ~ 8.005 | Calc |
| Ø10 | +0.005 | -0.010 | 9.990 ~ 10.005 | Calc |
| Ø12 | +0.006 | -0.012 | 11.988 ~ 12.006 | Calc |
| Ø13 | +0.006 | -0.012 | 12.988 ~ 13.006 | Calc |
| Ø16 | +0.006 | -0.012 | 15.988 ~ 16.006 | Calc |
| Ø20 | +0.006 | -0.015 | 19.985 ~ 20.006 | Calc |
| Ø25 | +0.006 | -0.015 | 24.985 ~ 25.006 | Calc |
| Ø30 | +0.006 | -0.015 | 29.985 ~ 30.006 | Calc |
| Ø35 | +0.007 | -0.018 | 34.982 ~ 35.007 | Calc |
| Ø40 | +0.007 | -0.018 | 39.982 ~ 40.007 | Calc |
| Ø50 | +0.007 | -0.018 | 49.982 ~ 50.007 | Calc |
| Ø60 | +0.009 | -0.021 | 59.979 ~ 60.009 | Calc |
| Ø80 | +0.009 | -0.021 | 79.979 ~ 80.009 | Calc |
| Ø100 | +0.010 | -0.025 | 99.975 ~ 100.010 | Calc |
| Fit | Type | Typical use |
|---|---|---|
| K7/h6 | Transition | General transition fit on the shaft-basis system, equivalent to H7/k6. K7 is common for the housing bore of rolling-bearing outer rings. |
The tolerance zones of the classes below lie entirely inside K7 (true for every size range from 0 to 500 mm), so they also satisfy a drawing that calls for K7. Those listed first are closest to K7; price and lead time still depend on material, size and stock.
It depends on the diameter. For Ø6, K7 means the part must measure between 5.991 and 6.003 mm, written 6(+0.003/-0.009). For other diameters see the chart above; every size range is listed.
Letters in uppercase denote a hole (inside diameter). In lowercase, k7 is a shaft tolerance, lying on the opposite side of the nominal size.
Yes. K6 is tighter than K7: at every diameter its limits fall inside the range K7 allows. The precision is simply higher than required, so the price may be a little higher.
Values follow ISO 286-1; the table was cross-checked cell by cell against three independent sources on 2026-08-26 (6,674 cells agree, 0 errors). Coverage: shafts a–z and the corresponding uppercase holes, IT1–IT13, nominal sizes 0–500 mm. cd/ef/fg/za/zb/zc, sizes above 500 mm and grades above IT13 are not included: the tool reports "not found" and never extrapolates. Data sources and verification →