SFP Precision — Hardware Parts Platform
中文English日本語
Home › Tolerance Calculator › Hole E8 tolerance chart

E8 Tolerance Chart (Hole E8)

Upper and lower deviations of hole E8 for nominal sizes 0–500 mm, per ISO 286-1. Values in mm; "+" means larger than nominal, "-" smaller. Calculate other sizes →

Nominal size (mm)Upper deviationLower deviationTolerance (IT)
0 ~ 3+0.028+0.0140.014
>3 ~ 6+0.038+0.0200.018
>6 ~ 10+0.047+0.0250.022
>10 ~ 18+0.059+0.0320.027
>18 ~ 30+0.073+0.0400.033
>30 ~ 50+0.089+0.0500.039
>50 ~ 80+0.106+0.0600.046
>80 ~ 120+0.126+0.0720.054
>120 ~ 180+0.148+0.0850.063
>180 ~ 250+0.172+0.1000.072
>250 ~ 315+0.191+0.1100.081
>315 ~ 400+0.214+0.1250.089
>400 ~ 500+0.232+0.1350.097

Each row applies to the whole size range shown. Ranges are "over the first value, up to and including the second".

How to read E8

E8 is an ISO 286 tolerance class. The uppercase letter E is the fundamental deviation (which side of the nominal size the tolerance zone lies on), and the number 8 is the tolerance grade IT8 (how wide the zone is). Easy running: E8/h7, E9/h9: high-speed or multi-bearing shafts, plain bearings that need a thicker oil film. Typical processes for IT8: turning, reaming, milling, broaching: fits of ordinary accuracy (H8, f7).

On a drawing or in a specification, Ø6 E8 and 6(+0.038/+0.020) mean the same thing — the second form writes the deviations out, so nobody has to look them up. SFP product specifications always use the second form.

Quick lookup for common sizes

Click "Calc" in the last column to open the calculator, where the written-out form can be copied with one click.

SizeUpper deviationLower deviationActual limits (mm)
Ø1+0.028+0.0141.014 ~ 1.028Calc
Ø1.5+0.028+0.0141.514 ~ 1.528Calc
Ø2+0.028+0.0142.014 ~ 2.028Calc
Ø2.5+0.028+0.0142.514 ~ 2.528Calc
Ø3+0.028+0.0143.014 ~ 3.028Calc
Ø4+0.038+0.0204.020 ~ 4.038Calc
Ø5+0.038+0.0205.020 ~ 5.038Calc
Ø6+0.038+0.0206.020 ~ 6.038Calc
Ø8+0.047+0.0258.025 ~ 8.047Calc
Ø10+0.047+0.02510.025 ~ 10.047Calc
Ø12+0.059+0.03212.032 ~ 12.059Calc
Ø13+0.059+0.03213.032 ~ 13.059Calc
Ø16+0.059+0.03216.032 ~ 16.059Calc
Ø20+0.073+0.04020.040 ~ 20.073Calc
Ø25+0.073+0.04025.040 ~ 25.073Calc
Ø30+0.073+0.04030.040 ~ 30.073Calc
Ø35+0.089+0.05035.050 ~ 35.089Calc
Ø40+0.089+0.05040.050 ~ 40.089Calc
Ø50+0.089+0.05050.050 ~ 50.089Calc
Ø60+0.106+0.06060.060 ~ 60.106Calc
Ø80+0.106+0.06080.060 ~ 80.106Calc
Ø100+0.126+0.072100.072 ~ 100.126Calc

Alternative classes (tighter)

The tolerance zones of the classes below lie entirely inside E8 (true for every size range from 0 to 500 mm), so they also satisfy a drawing that calls for E8. Those listed first are closest to E8; price and lead time still depend on material, size and stock.

E7E6

Related tolerance charts

FAQ

How big is E8 exactly?

It depends on the diameter. For Ø6, E8 means the part must measure between 6.020 and 6.038 mm, written 6(+0.038/+0.020). For other diameters see the chart above; every size range is listed.

Is E8 a hole tolerance or a shaft tolerance?

Letters in uppercase denote a hole (inside diameter). In lowercase, e8 is a shaft tolerance, lying on the opposite side of the nominal size.

The drawing calls for E8 but the parts I have are E7. Can I use them?

Yes. E7 is tighter than E8: at every diameter its limits fall inside the range E8 allows. The precision is simply higher than required, so the price may be a little higher.

Tell us the tolerance on your drawing and we will match it to stock. Write the size as 8(0/-0.015) or 8h7 and e-mail it with material, length and quantity to sfp@sfp-tw.com, or check availability directly in the online catalog. Stock dowel pins come in h6 / h7 / m6 as well as minus and plus tolerance; whenever the tolerance zone of a stock part lies entirely within the acceptance range on your drawing, it can ship straight away with no wait for custom production.

Values follow ISO 286-1; the table was cross-checked cell by cell against three independent sources on 2026-08-26 (6,674 cells agree, 0 errors). Coverage: shafts a–z and the corresponding uppercase holes, IT1–IT13, nominal sizes 0–500 mm. cd/ef/fg/za/zb/zc, sizes above 500 mm and grades above IT13 are not included: the tool reports "not found" and never extrapolates. Data sources and verification →

🔍 Open the online catalog🧮 Tolerance calculator